Daikin BRC1C71 Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Klimatyzatory typu split Daikin BRC1C71. Daikin BRC1C71 Instruction manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 92
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 2 - Controls

EDUS39-605 Control DevicesControls 92.1.7 Field Setting Wired Remote Controller BRC1C71Field Setting Contents and Code No.If optional accessories are

Strona 3 - 1. Control Systems

Control Devices EDUS39-60510 ControlsNotes:1. Setting is carried out in the group mode. If the mode number inside the parentheses is selected, indoor

Strona 4 - 2. Control Devices

EDUS39-605 Control DevicesControls 112.2 BRC4C / 7C / 7E Wireless Remote Controller / Receiver BRC7C812 BRC4C82C:3D005912D2-7/16 11/166-3/16C:3D0078

Strona 5 - 2.1.4 Group Control

Control Devices EDUS39-60512 Controls BRC7E83 BRC7E8183D049336C:3D034905B2-7/1611/166-3/16

Strona 6

EDUS39-605 Control DevicesControls 132.3 BRC2A71 Simplified Remote Controller2.3.1 Name and FunctionDISPLAY Ò Ó (CHANGEOVER UNDER CONTROL)DIS

Strona 7

Control Devices EDUS39-60514 Controls2.3.2 Installation3P146205-11. Remove the upper part of remote controller.Insert a minus screwdriver into the slo

Strona 8 - 2.1.6 Installation

EDUS39-605 Control DevicesControls 152.3.3 Dimensions5. Reattach the upper part of remote controller.NOTE1. Do not directly touch the PC board with y

Strona 9 - 18 – 2AWG

Control Devices EDUS39-60516 Controls2.4 DCS302C71 Central Remote Controller2.4.1 System ConfigurationSystem Outline You can connect up to 64 groups

Strona 10 - 2P068938

EDUS39-605 Control DevicesControls 17System Configuration for Group / Zone Control Group control Group control configuration allows all indoor units

Strona 11 - 18-2 AWG

Control Devices EDUS39-60518 ControlsSystem Configuration (Control by 2 central remote controllers) Up to 128 indoor units can be connected in one sy

Strona 12 -  BRC4C82

EDUS39-605A-CControls 1Controls1. Control Systems...22. Control

Strona 13 - C:3D034905B

EDUS39-605 Control DevicesControls 192.4.2 Specifications / DimensionsSpecificationsDimensionsDCS302C71DCS302C71Power supply voltage / frequency AC100

Strona 14 - 2.3.1 Name and Function

Control Devices EDUS39-60520 Controls2.4.3 Names and Functions of Operating Part Display part DISPLAY (OPERATION MODE) Displays operating state. Con

Strona 15 - 3P146205-1

EDUS39-605 Control DevicesControls 212.4.4 Description of FunctionsIndividual Screen, All Screen, Zone ScreenThis controller can perform operations in

Strona 16 - "MAIN."

Control Devices EDUS39-60522 ControlsCool/Heat changeover and settingsNOTE:Cool/heat Mode-setting capability for the Indoor Unit Remote Controller: T

Strona 17 - System Outline

EDUS39-605 Control DevicesControls 23 Use the following procedure to set operation mode:  Description of operation and its function:Note: Selection

Strona 18

Control Devices EDUS39-60524 ControlsControl with Two Central Remote ControllersThe central remote control equipment is the newly designed C type tha

Strona 19

EDUS39-605 Control DevicesControls 25Sequential StartOperation command from central control equipmentEach unit operates in sequence. For example, if

Strona 20 - Dimensions

Control Devices EDUS39-60526 ControlsBatch deletion of zone registration1. Pressing the ALL for at least four seconds while pressing the FILTER S

Strona 21 -  Control Section

EDUS39-605 Control DevicesControls 27Changing the Fan Direction and Fan StrengthChanging the fan direction and strength is accessed from the following

Strona 22 - Zone control functions

Control Devices EDUS39-60528 Controls2. Once the desired timer number is displayed, press the SET button.Press the SET button within 10 seconds after

Strona 23

Control Systems EDUS39-6052 Controls1. Control SystemsOptional Accessories of Operation Control System C:3D043022CNotes:1. Installation box (No.4)

Strona 24 - changeover

EDUS39-605 Control DevicesControls 292.4.5 Wiring InstructionsWiring instructionsFor control wiring of DIII-NET, you can select from the following 3 t

Strona 25

Control Devices EDUS39-60530 Controls2.4.6 Instructions for Initial SettingGroup No. Setting for Central Control EquipmentGroup No. should be set for

Strona 26 - Registering Zone

EDUS39-605 Control DevicesControls 31Cautions Even in the systems without remote control, connect the remote controller once to set the Group Numbe

Strona 27 - Monitor in a zone unit

Control Devices EDUS39-60532 Controls2.4.7 Selection of Control Mode No. Select whether to accept or reject operations by local remote controller such

Strona 28 - Timer Number Setting

EDUS39-605 Control DevicesControls 33 Timing Chart for Scheduled Operation and each Control Mode No. (VRV system) are as follows:1. Remote controller

Strona 29

Control Devices EDUS39-60534 Controls5. Remote controller permission timer: Code No. 8, 9, 18, 19 Note: Operation by remote controller is the same as

Strona 30 - Wiring instructions

EDUS39-605 Control DevicesControls 352.4.8 Setting of Central Remote Controller: Be sure to set 1 ~ 3 before electrical power is supplied.1. Connector

Strona 31 - Unit NO

Control Devices EDUS39-60536 Controls4. Forced reset switchWhen changing the setting of the connector for the main controller, you can reset simply

Strona 32

EDUS39-605 Control DevicesControls 37Examples of functionality with Refreshed Operation: If the setting is changed by DCS302C71, the unit operates

Strona 33

Control Devices EDUS39-60538 ControlsSetting Contents and Setting No.Items in bold represent the factory set for the No. of Switch Setting.Do not mak

Strona 34

EDUS39-605 Control DevicesControls 32. Control Devices2.1 BRC1C71 Wired Remote ControllerThe optional Remote Controller for indoor units provides vers

Strona 35 - 34 Controls

EDUS39-605 Control DevicesControls 39Installation(1) Open the upper part of remote controller. Insert a screwdriver (2 locations) into the recess bet

Strona 36

Control Devices EDUS39-60540 Controls2.5 DCS301C71 Unified ON/OFF ControllerTurns up to 16 groups of indoor units (max. 128 units) on/off (operation/s

Strona 37 - No. of Switch Setting

EDUS39-605 Control DevicesControls 41The groups of indoor units are as follows:1. One indoor unit without remote controller2. One indoor unit controll

Strona 38 - Fan Mode Fan Operation

Control Devices EDUS39-60542 ControlsExamples of Wiring for Transmission1. Series Wiring2. Bus Type Wiring: Can be branched up to 16 branchesExample o

Strona 39

EDUS39-605 Control DevicesControls 43Wiring to the Indoor Unit and Outdoor UnitWARNING:Do not connect the power supply wiring to the control terminal

Strona 40 - Installation

Control Devices EDUS39-60544 Controls2.5.4 Installation1. Open the upper part of remote controller.Insert a minus screwdriver (2 locations) into the r

Strona 41 - 2.5.1 System Configuration

EDUS39-605 Control DevicesControls 452. Switch for Setting Each Address (DS1) The following switches are used to set group control address:Group Numb

Strona 42 - Wiring Outline

Control Devices EDUS39-60546 Controls5. Control Mode Selector (DS2)The following four patterns of control mode can be set:Note: Indicates the positi

Strona 43

EDUS39-605 Control DevicesControls 472.5.6 Setting Group No. for Centralized ControlSet the group number of each group of the indoor unit from the rem

Strona 44 - 2.5.3 Dimensions

Control Devices EDUS39-60548 Controls2.6 DST301BA61 Schedule TimerEnables you to connect and control weekly schedules for up to 128 indoor units.2.6.1

Strona 45 - 2.5.5 Initial Setting

Control Devices EDUS39-6054 Controls2.1.3 Two Remote Controllers1 indoor unit is controlled by 2 remote controllers from 2 separate locationsThis is a

Strona 46

EDUS39-605 Control DevicesControls 492.6.2 Names and Functions DST301BA613P124623-5C1 236497810 115DST301BA61Fig. 11715 14121318 19 2016DST301BA61Fig.

Strona 47

Control Devices EDUS39-60550 Controls1UNIFIED OPERATION BUTTON Press to perform the unified operation regardless of the programmed time.2UNIFIED ST

Strona 48 - 2.5.7 Confirming Operation

EDUS39-605 Control DevicesControls 512.6.3 DimensionSchedule Timer DST301BA61C:3D0495442.6.4 Installation and Initial Setting1. Remove the upper part

Strona 49 - 2.6 DST301BA61 Schedule Timer

Control Devices EDUS39-60552 Controls Attach the lower part to the electrical box (part to be procured in the field) with the provided installation s

Strona 50 - DST301BA61

EDUS39-605 Control DevicesControls 534. Forced Reset Switch (SS1) When changing the setting of the connector for individual use, the switch can be re

Strona 51

Control Devices EDUS39-60554 Controls4. Install the Upper Part of the Remote Controller as before.2.6.5 Error Diagnosing FunctionThis schedule timer i

Strona 52 - Schedule Timer

EDUS39-605 Control DevicesControls 552.7 BRC1D71 7-Day Programmable Controller New, advanced functions are as follows: 2.7.1 Dimension BRC1D71 Inc

Strona 53 - 2. Initial Setting

Control Devices EDUS39-60556 Controls2.7.2 Features and FunctionsThe BRC1D71 is a state-of-the-art remote controller that offers full control. 1 BASI

Strona 54 - 3. Transmission Wiring

EDUS39-605 Control DevicesControls 572.7.4 Name and Function of Switches and Icons (Refer to figure 1)1 ON/OFF BUTTON Press the ON/OFF button to start

Strona 55

Control Devices EDUS39-60558 Controls26 VENTILATION MODE BUTTON The ventilation mode button operates the ; refer to the manual for more details.27

Strona 56 - Unit (in.)

EDUS39-605 Control DevicesControls 52.1.5 Remote Controller and Changeover Switch: Name and Function of Each Switch and Display1. ON/OFF buttonPress t

Strona 57 - Figure 1

EDUS39-605 Control DevicesControls 592.7.5 InstallationThe kit includes the following parts:1. Remove the upper part of remote controller Insert a min

Strona 58

Control Devices EDUS39-60560 ControlsIf controlling one indoor unit or one group of indoor units with two remote controllersChange the MAIN/SUB change

Strona 59 - 3P166742-1

EDUS39-605 Control DevicesControls 613P166742-2Mode No.Note 1FIRST CODE NO.Description of setting SECOND CODE NO. Note 201 02 03 0410(20)0Filter Conta

Strona 60 - 2.7.5 Installation

Control Devices EDUS39-60562 Controls2.8 DCS601C71 intelligent Touch Controller2.8.1 FeaturesCentral remote controller offering more advanced function

Strona 61 - UNIT No

EDUS39-605 Control DevicesControls 63 Handy Automated ControlThe intelligent Touch Controller offers the following automated controls: • Change Over

Strona 62

Control Devices EDUS39-60564 Controls2.8.3 Options3P073677-15T2.8.4 SpecificationSpecificationDimensionThe specification and appearance of the product

Strona 63 - 2.8.1 Features

EDUS39-605 Control DevicesControls 652.8.5 Part Names and Functions3P073677-15TBe sure to use the touch pen for operation of the touch panel of the in

Strona 64 - 2.8.2 System Overview

Control Devices EDUS39-60566 Controls2.8.6 Monitoring Screen Labels and Functions75˚FContents of the List Currently DisplayedyWhen Group List is displ

Strona 65 - 2.8.4 Specification

EDUS39-605 Control DevicesControls 67IconsContents of the List Currently DisplayedyWhen Group List is displayed“Zone: Zone Name”yWhen Zone List is dis

Strona 66 - Touch Pen

Control Devices EDUS39-60568 ControlsLists:Contents of the List Currently DisplayedyWhen Group List is displayed“Zone: Zone Name”yWhen Zone List is di

Strona 67 - EM05A058

Control Devices EDUS39-6056 ControlsRefer to the indoor unit manual.19.Fan speed control buttonSelect the fan speed. 20.Operation mode selector button

Strona 68 - Controls 67

EDUS39-605 Control DevicesControls 692.8.7 Electrical Wiring Connection

Strona 69 - 68 Controls

Control Devices EDUS39-60570 Controls

Strona 70 - Controls 69

EDUS39-605 Control DevicesControls 71

Strona 71 - 70 Controls

Control Devices EDUS39-60572 Controls1P167242A

Strona 72 - Controls 71

EDUS39-605 Control DevicesControls 732.8.8 DCS004A71 Web Software for the intelligent Touch ControllerFunctions and OutlineThis software enables you t

Strona 73 - 72 Controls

Adaptors EDUS39-60574 Controls3. Adaptors3.1 KRCS01-1 Remote SensorThe built-in temperature control thermistor of the indoor unit is mounted in the in

Strona 74 - Functions and Outline

EDUS39-605 AdaptorsControls 753.2 DTA104A 53/ 61/ 62 Required Outdoor Unit External Control Adaptor C:1PA63164D-1Must be installed on Indoor Units

Strona 75 - 3. Adaptors

Adaptors EDUS39-60576 ControlsC:1PA63164D-2

Strona 76 - C:1PA63164D-1

EDUS39-605 AdaptorsControls 773.3 DTA109A51 DIII NET Expander Adaptor

Strona 77 - C:1PA63164D-2

Adaptors EDUS39-60578 Controls

Strona 78 - Controls 77

EDUS39-605 Control DevicesControls 72.1.6 Installation

Strona 79 - 78 Controls

EDUS39-605 AdaptorsControls 79

Strona 80 - Controls 79

Adaptors EDUS39-60580 Controls3.4 KRP1B71 / 72 / 73 Adaptor for wiring

Strona 81 - 80 Controls

EDUS39-605 AdaptorsControls 81C:2P164806

Strona 82 - C:2P164806

Adaptors EDUS39-60582 Controls3.5 KRP4A71 / 72 / 73 / 74 Wiring Adaptor for Electrical Appendices

Strona 83 - 82 Controls

EDUS39-605 AdaptorsControls 831P161220

Strona 84 - 1P161220

Adaptors EDUS39-60584 Controls

Strona 85 - 84 Controls

EDUS39-605 AdaptorsControls 85

Strona 86 - Controls 85

Adaptors EDUS39-60586 ControlsC:1P161221

Strona 87 - 86 Controls

EDUS39-605 AdaptorsControls 873.6 DCS302A72 Unification Adaptor for Computerized Control3.6.1 FunctionWhen connected to the central remote controller,

Strona 88 - 3.6.1 Function

Adaptors EDUS39-60588 Controls3.6.3 Installation Securely install the adaptor inside the electric panel box (field supplied) with the 4 attached scre

Strona 89 - 3.6.3 Installation

Control Devices EDUS39-6058 Controls18 – 2AWG

Strona 90

EDUS39-605 AdaptorsControls 89Wiring to External Input DevicesWire specifications: 2- conductor, 18 AWG, stranded, non-shielded copper cable / PVC or

Strona 91

Adaptors EDUS39-60590 Controls2. Control Mode Switch (RS1) Setting(1) For Normal Operation by Input A Input B can be disregarded.(2) For Instantaneou

Strona 92 - EDUS 39 - 600 - F2

EDUS 39 - 600 - F2AMERICASFXDQ-MSlim Ceiling Mounted Duct Type1645 Wallace Drive, Suite 110Carrollton, [email protected]

Komentarze do niniejszej Instrukcji

Brak uwag