EDUS39-600-F5 Capacity Tables
FXHQ-M 11
7.2 Heating Capacity
FXHQ-M
Refer to Outdoor Unit Capacity Tables : for the actual performance data of each indoor and outdoor unit combination.
Heating Capacity
Indoor unit
Outdoor Air Temp.
Indoor Air Temp. °FDB
62 65 68 70 72 75
TC TC TC TC TC TC
°FDB °FWB MBh MBh MBh MBh MBh MBh
12
22.0 20.0 11.7 11.7 11.6 11.6 11.6 11.6
26.0 24.0 12.2 12.2 12.2 12.2 12.2 12.1
30.0 28.0 12.8 12.8 12.7 12.7 12.7 12.3
35.0 32.0 13.3 13.3 13.3 13.3 13.0 12.3
39.0 36.0 13.9 13.9 13.9 13.5 13.0 12.3
44.0 40.0 14.5 14.4 14.0 13.5 13.0 12.3
47.0 43.0 14.9 14.7 14.0
13.5 13.0 12.3
51.0 47.0 15.4 14.7 14.0 13.5 13.0 12.3
54.0 50.0 15.5 14.7 14.0 13.5 13.0 12.3
57.0 53.0 15.5 14.7 14.0 13.5 13.0 12.3
60.0 56.0 15.5 14.7 14.0 13.5 13.0 12.3
24
22.0 20.0 23.3 23.3 23.3 23.2 23.2 23.2
26.0 24.0 24.5 24.4 24.4 24.3 24.3 24.3
30.0 28.0 25.6 25.5 25.5 25.5 25.4 24.5
35.0 32.0 26.7 26.6 26.6 26.6 26.0 24.5
39.0 36.0 27.8 27.7 27.7 27.0 26.0 24.5
44.0 40.0 28.9 28.9 28.0 27.0 26.0 24.5
47.0 43.0 29.7 29.5 28.0
27.0 26.0 24.5
51.0 47.0 30.8 29.5 28.0 27.0 26.0 24.5
54.0 50.0 31.0 29.5 28.0 27.0 26.0 24.5
57.0 53.0 31.0 29.5 28.0 27.0 26.0 24.5
60.0 56.0 31.0 29.5 28.0 27.0 26.0 24.5
36
22.0 20.0 35.0 35.0 34.9 34.8 34.8 34.7
26.0 24.0 36.7 36.6 36.6 36.5 36.5 36.4
30.0 28.0 38.4 38.3 38.2 38.2 38.1 36.8
35.0 32.0 40.0 40.0 39.9 39.8 39.0 36.8
39.0 36.0 41.7 41.6 41.6 40.0 39.0 36.8
44.0 40.0 43.4 43.3 42.0 40.0 39.0 36.8
47.0 43.0 44.6 44.2 42.0
40.0 39.0 36.8
51.0 47.0 46.3 44.2 42.0 40.0 39.0 36.8
54.0 50.0 46.5 44.2 42.0 40.0 39.0 36.8
57.0 53.0 46.5 44.2 42.0 40.0 39.0 36.8
60.0 56.0 46.5 44.2 42.0 40.0 39.0 36.8