CAUTION
Drain piping connections
Do not connect the drain piping directly to sewage pipes that
smell of ammonia. The ammonia in the sewage might enter
the indoor unit through the drain pipes and corrode the heat
exchanger.
Keep in mind that it will become the cause of getting drain
pipe blocked if water collects on drain pipe.
8. ELECTRIC WIRING WORK
8-1 GENERAL INSTRUCTIONS
All field supplied parts and materials, electric works conform
to local codes.
Use copper wire only.
Follow the “WIRING DIAGRAM” attached to the unitbody to
wire the outdoor unit, indoor units and the remote controller.
For details on hooking up the remote controller, refer to the
“INSTALLATION MANUAL OF REMOTE CONTROLLER.
All wiring must be performed by an authorized electrician.
This system consists of multiple indoor units. Mark each
indoor unit as unit A, unit B . . . , and be sure the terminal
board wiring to the outdoor unit and BS unit are properly
matched. If wiring and piping between the outdoor unit and
an indoor unit are mismatched, the system may cause a mal-
function.
A circuit breaker capable of shutting down the power supply
to the entire system must be installed.
Refer to the installation manual attached to the outdoor unit
for the size of power supply wiring connected to the outdoor
unit, the capacity of the circuit breaker and switch, and wiring
instructions.
Be sure to ground the air conditioner.
Do not connect the ground wire to gas and water pipes, light-
ning rods, or telephone ground wires.
Gas pipes
:
might
cause explosions or fire if gas leaks.
Water pipes : no grounding effect if hard vinyl piping is used.
Telephone ground wires or lightning rods : might cause
abnormally high electric potential in the ground during
lighting storms.
8-2 ELECTRICAL CHARACTERISTICS
MCA: Min. Circuit Amps (A); MFA: Max. Fuse Amps (A)
kW: Fan Motor Rated Output (kW); FLA: Full Load Amps (A)
8-3 SPECIFICATIONS FOR FIELD SUPPLIED
FUSES AND WIRE
NOTE
1. Allowable length of transmission wiring between indoor /
outdoor units and between the indoor unit and the remote
controller is as follows.
(1) Outdoor unit – Indoor unit:
Max. 1000 m (Total wiring length: 2000 m)
(2) Indoor unit – Remote controller:
Max. 500 m
9. WIRING EXAMPLE AND HOW TO SET
THE REMOTE CONTROLLER
9-1 HOW TO CONNECT WIRINGS
Remove the electric parts box lid and connect the wiring.
NOTE
For electric parts box wiring, also see “Electric Wiring Dia-
gram” label.
Remote controller wiring, transmission wiring
Do not confuse the two when connecting to the terminal
block for remote controller.
Fasten the wiring with accessory clamp (6).
If mounting a remote con-
troller on the unit, wire as
shown in the figure on the
right.
Units
Power
supply
Fan motor
Model Hz Volts
Voltage
range
MCA MFA kW FLA
FXLQ20 · 25M(A)VE,
FXNQ20 · 25M(A)VE
50
220-
240
Max. 264
Min. 198
0.3 15 0.015 0.2
FXLQ32 · 40M(A)VE,
FXNQ32 · 40M(A)VE
0.6 15 0.025 0.5
FXLQ50 · 63M(A)VE,
FXNQ50 · 63M(A)VE
0.6 15 0.035 0.5
FXLQ20 · 25M(A)VE,
FXNQ20 · 25M(A)VE
60 220
Max. 242
Min. 198
0.3 15 0.015 0.2
FXLQ32 · 40M(A)VE,
FXNQ32 · 40M(A)VE
0.5 15 0.025 0.4
FXLQ50 · 63M(A)VE,
FXNQ50 · 63M(A)VE
0.6 15 0.035 0.5
Model
Power supply wiring
Remote controller wiring
Transmission wiring
Field
fuses
Wire Size Wire Size
FXLQ20 · 25 ·
32 · 40 ·
50 · 63M(A)VE
15A
H05VV
-U3G
Size must
comply
with local
codes.
Sheathed
wire
(2 wire)
0.75 - 1.25
mm
2
FXNQ20 · 25 ·
32 · 40·
50 · 63M(A)VE
Electric parts box
Clamp fastener
Transmission
wiring (*)
Clamp
(accessory)
Cut off excess after fastening.
Power supply wiring,
ground wiring (*)
(Field wiring)
Remote controller wiring (*)
(Field wiring)
Transmission wiring (*)
(Field wiring)
Pass through hole
of remote
controller
fastening plate.
Remote
controller wiring
01_EN_3P086154-2P.fm Page 7 Tuesday, March 31, 2009 5:26 PM
Przeglądanie stron 8
1 2 3 4 5 6 7 8 9 10 11 12 13

Komentarze do niniejszej Instrukcji

Brak uwag