Daikin BRC7E65 Dokumentacja Strona 134

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 133
Si38-606 Troubleshooting by Indication on the Remote Controller
Troubleshooting 123
2.5
A7
Indoor Unit: Malfunction of Swing Flap Motor (MA)
Remote
Controller
Display
A7
Applicable
Models
FXC, FXA, FXF, FXH, FXK
Method of
Malfunction
Detection
Utilizes ON/OFF of the limit switch when the motor turns.
Malfunction
Decision
Conditions
When ON/OFF of the microswitch for positioning cannot be reversed even though the swing flap
motor is energized for a specified amount of time (about 30 seconds).
Supposed
Causes
Defect of swing motor
Defect of connection cable (power supply and limit switch)
Defect of air flow direction adjusting flap-cam
Defect of indoor unit PC board
Przeglądanie stron 133
1 2 ... 129 130 131 132 133 134 135 136 137 138 139 ... 253 254

Komentarze do niniejszej Instrukcji

Brak uwag