EDUS 39 - 900 - F8
AMERICAS
BSVQ-P
BS units
EDUS39-900-F8
Printed in U.S.A. 11/09 FS.K
Specifications, designs and other content appearing in this brochure are current as of November 2009 but subject to change without notice.
1645 Wallace Drive, Suite 110
Carrollton, TX75006
www.daikinac.com
AMERICAS
Przeglądanie stron 0
1 2 3 4 5 6 ... 29 30

Podsumowanie treści

Strona 1 - BS units

EDUS 39 - 900 - F8AMERICASBSVQ-PBS unitsEDUS39-900-F8Printed in U.S.A. 11/09 FS.KSpecifications, designs and other content appearing in this brochure

Strona 2

EDUS39-900-F8 Safety devices settingBSVQ-P 96. Safety devices setting4D057956BModel BSVQ36PVJU BSVQ60PVJU BSVQ96PVJUPC board fuse 250V 3.15A 250V 3.15

Strona 3 - 1. Specifications

Sound levels EDUS39-900-F810 BSVQ-P7. Sound levels7.1 Overall7.2 Octave band level208~230V, 60Hz Location of microphone Notes:1. Operation noise diff

Strona 4 - 2. Dimensions

EDUS39-900-F8 Center of gravityBSVQ-P 118. Center of gravityBSVQ36PVJUBSVQ60PVJU3D059694BSVQ96PVJU3D065542

Strona 5 - BSVQ60PVJU

Installation EDUS39-900-F812 BSVQ-P9. Installation3P194121-3M1 EnglishBSVQ36PVJUBSVQ60PVJUBSVQ96PVJUVRVIII SYSTEM Air ConditionersInstallation manualC

Strona 6 - 3D065540

EDUS39-900-F8 InstallationBSVQ-P 133P194121-3MEnglish 2• After completing the installation work, check that the refrigerant gas does not leak througho

Strona 7 - 3. Piping diagrams

Installation EDUS39-900-F814 BSVQ-P3P194121-3M3 English• Install drain piping to proper drainage. Improper drain piping may result in water leakage an

Strona 8 - 4. Wiring diagrams

EDUS39-900-F8 InstallationBSVQ-P 153P194121-3MEnglish 4NOTEThe refrigerant R410A requires strict cautions for keeping the system clean, dry and tight.

Strona 9 - 5. Electric characteristics

Installation EDUS39-900-F816 BSVQ-P3P194121-3M5 English2-4 COMBINATION• This BS unit is only applicable to VRV-III (REYQ__P) or VRV-WIII (RWEYQ__P) se

Strona 10 - 6. Safety devices setting

EDUS39-900-F8 InstallationBSVQ-P 173P194121-3MEnglish 6Note: The Electrical Components Box mounting surface can be changed.For information on how to c

Strona 11 - 7. Sound levels

Installation EDUS39-900-F818 BSVQ-P3P194121-3M7 English5. BS UNIT INSTALLATIONUse only accessories and parts which are of the designated specification

Strona 12 - 8. Center of gravity

EDUS39-900-F8BSVQ-P 1BSVQ-PBS units1. Specifications ...22.

Strona 13 - 9. Installation

EDUS39-900-F8 InstallationBSVQ-P 193P194121-3MEnglish 86. REFRIGERANT PIPING WORK• For instruction for installing piping between the outside unit and

Strona 14 - BSVQ-P 13

Installation EDUS39-900-F820 BSVQ-P3P194121-3M9 English6-3 PIPING CONNECTION WORK PRECAUTIONS• When brazing refrigerant piping, begin working after re

Strona 15 - 14 BSVQ-P

EDUS39-900-F8 InstallationBSVQ-P 213P194121-3MEnglish 10Table 1 Indoor unit total capacity and pipe sizeTable 2 Indoor unit connection pipe size*

Strona 16 - 2. BEFORE INSTALLATION

Installation EDUS39-900-F822 BSVQ-P3P194121-3M11 EnglishSuction gas pipe (Site piping)HP/LP gas pipe (Site piping)Gas pipe (Site piping)Liquid pipe (S

Strona 17 - 2-5 CHECK ITEM

EDUS39-900-F8 InstallationBSVQ-P 233P194121-3MEnglish 126-6 PIPING INSULATION• After the gas leak inspection is completed, refer to the following figu

Strona 18 - BSVQ-P 17

Installation EDUS39-900-F824 BSVQ-P3P194121-3M13 English7. ELECTRIC WIRING WORK7-1 GENERAL INSTRUCTIONS• All wiring must be performed by an authorized

Strona 19 - 5. BS UNIT INSTALLATION

EDUS39-900-F8 InstallationBSVQ-P 253P194121-3MEnglish 14Table 3 MCA: Min. Circuit Amps (A); MFA: Max. Fuse Amps (A)NOTES• The above Table 3 of Electr

Strona 20 - 6. REFRIGERANT PIPING WORK

Installation EDUS39-900-F826 BSVQ-P3P194121-3M15 English7-5 WIRING CONNECTIONSRemove the Electrical Components Box lid on the side and follow the dire

Strona 21 - 6-4 PIPING SIZE SELECTION

EDUS39-900-F8 InstallationBSVQ-P 273P194121-3MEnglish 16NOTES• Use ring-type crimp style terminal for connections to the power terminal block. (Refer

Strona 22 - BSVQ36P type

Installation EDUS39-900-F828 BSVQ-P3P194121-3M17 English¢Setting description²• The “Automatic mode differential” can be changed within the range of 0°

Strona 23 - BSVQ96P type

Specifications EDUS39-900-F82 BSVQ-P1. SpecificationsBS unitsNotes:+1 In case of connecting with a 07~18 type indoor unit, match to the size of field

Strona 24 - BSVQ36 · 60P type

EDUS 39 - 900 - F8AMERICASBSVQ-PBS unitsEDUS39-900-F8Printed in U.S.A. 12/09 FS.KSpecifications, designs and other content appearing in this brochure

Strona 25 - 7. ELECTRIC WIRING WORK

EDUS39-900-F8 DimensionsBSVQ-P 32. DimensionsBSVQ36PVJUφ 3/8 brazing connectionDescriptionφ 3/8 brazing connectionLiquid pipe connection portSuction g

Strona 26 - 7-4 WIRING EXAMPLE

Dimensions EDUS39-900-F84 BSVQ-PBSVQ60PVJU(Servicing space)(Suspension bolt pitch)(Suspension bolt pitch)8-5/8(8-5/8)(8-9/16)1216-7/8(8-9/16) 18 (Note

Strona 27 - TO IN/D UNIT TO OUT/D UNIT

EDUS39-900-F8 DimensionsBSVQ-P 5BSVQ96PVJU3D065540an

Strona 28 - 8. INITIAL SETTING

Piping diagrams EDUS39-900-F86 BSVQ-P3. Piping diagrams4D057985B

Strona 29 - 9. TEST OPERATION

EDUS39-900-F8 Wiring diagramsBSVQ-P 74. Wiring diagrams3D058235C

Strona 30

Electric characteristics EDUS39-900-F88 BSVQ-P5. Electric characteristics4D058238A