INSTALLATION
MANUAL
R410A Split Series
Models
RXN15KEVJU RKN15KEVJU
RXN18KEVJU RKN18KEVJU
RXN24KEVJU RKN24KEVJU
00_CV_3P273470-2.indd 100_CV_3P273470-2.indd 1 12/15/2010 2:29:23 PM12/15/2010 2:29:23 PM
Przeglądanie stron 0
1 2 3 4 5 6 ... 13 14

Podsumowanie treści

Strona 1 - INSTALLATION

EnglishInstallation manualR410A Split seriesFrançaisEspañolManuel d’installationSérie split R410AManual de instalaciónSerie Split R410AINSTALLATION MA

Strona 2 - Safety Precautions

9EnglishPump Down OperationIn order to protect the environment, be sure to pump down when relocating or disposing of the unit.1) Remove the valve ca

Strona 3 - Accessories

10EnglishWiring WARNINGDo not use tapped wires, stranded wires, extension cords, or starburst connections, as they may cause overheating, electrical

Strona 4 - CAUTION

11English CAUTIONWhen connecting the connection wires to the terminal board • using a single core wire, be sure to perform curling. Problems with th

Strona 5 - English

12EnglishTrial Operation and TestingTrial operation and testing1. Measure the supply voltage and make sure that it falls in the specifi ed range.1-1 T

Strona 6 - Outdoor Unit Installation

3P273470-2 M10B141(1102)HTTwo-dimensional bar code is a code for manufacturing.00_CV_3P273470-2.indd 200_CV_3P273470-2.indd 2 12/15/2010 2:29

Strona 7

1EnglishSafety PrecautionsRead these Safety Precautions carefully to ensure correct installation.• This manual classifi es the precautions into DANGER

Strona 8

2EnglishSafety Precautions WARNINGAfter connecting all wires be sure to shape the cables so that they do not put undue stress on the electrical • cov

Strona 9

3EnglishPrecautions for Selecting the LocationChoose a place solid enough to bear the weight and vibration of the unit, where the operation noise wil

Strona 10 - Pump Down Operation

4EnglishOutdoor Unit Installation Drawings Allow space for piping and electrical servicing.(Foot bolt-hole centers)CAUTION**Set the piping length

Strona 11 - WARNING

5EnglishInstallation Guidelines Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airfl ow, follow the installation guid

Strona 12 - Facility Setting

6EnglishOutdoor Unit Installation3. Flaring the pipe end Cut the pipe end with a pipe cutter.1) Remove burrs with the cut surface facing 2) downward

Strona 13 - Trial Operation and Testing

7EnglishPurging air and checking gas leakage5. When piping work is completed, it is necessary to purge the air and check for gas leakage.• WARNINGD

Strona 14 - 3P273470-2

8EnglishOutdoor Unit InstallationRefi lling the refrigerant6. Check the type of refrigerant to be used on the machine nameplate.Precautions when addin