3
Dimensional drawings
FH(Y)C35-71B7
view A
680 Suspension position
B view
780 (Suspension position)
860890 (Ceiling opening)
Note:
1. Location of unit’s name plate
Main body: bell mouth inside the suction grille.
Decoration panel: panel inner frame inside the suction grille..
2. When installing an optional accessory, refer to the installation drawings.
+ For fresh air intake kit - inspection port is necessary
+ For high efficiency filter unit - inspection port is not necessary.
+ For branch duct chamber - inspection port is not necessary.
1 Liquid pipe connection J6.4 Flare connection
2 Gas pipe connectionJ12.7 Flare connection
3 Drain pipe connection VP25 (O.D. J32)
4 Power supply connection
5 Remote control code and control wiring connection
6 Air discharge grille
7 Air suction grille
8 Port for water supply
9 Corner decoration cover
10 Drain hose O.D.J32
z When the discharge grill is closed, the
required space is 200mm or more
860890 (Ceiling opening)
Adjustable(0550)
Hanging bolt
1000 mm or
more
Branch duct
connection
Required service
space
Prepared hole
1500 mm
or more
Required service space
1500 mm or more
1500 mm or more
1500 mm or more
For fresh air intake kit
connection
(direct installation type)
Branch duct connection
Note 3
300 or less
3TW22834-1
3. In case of using infrared remote controller, this position will be a signal
receiver.
Refer to the drawing of infrared remote controller in detail
4. When it may exceed 30°C and RH 80% in the ceiling or fresh air is
inducted into the ceiling, an additional insulation (Thickness 10mm or
more of glasswool or polyethylene form) is required.
Prepared hole
Branch duct connection
Prepared hole
D view
Prepared hole
view C
FH(Y)C100-125B7
view A
680 Suspension position
B view
780 (Suspension position)
860890 (Ceiling opening)
Note:
1. Location of unit’s name plate
Main body: bell mouth inside the suction grille.
Decoration panel: panel inner frame inside the suction grille..
2. When installing an optional accessory, refer to the installation drawings.
+ For fresh air intake kit - inspection port is necessary
+ For high efficiency filter unit - inspection port is not necessary.
+ For branch duct chamber - inspection port is not necessary.
1 Liquid pipe connection J6.4 Flare connection
2 Gas pipe connectionJ15.9 Flare connection
3 Drain pipe connection VP25 (O.D. J32)
4 Power supply connection
5 Remote control code and control wiring connection
6 Air discharge grille
7 Air suction grille
8 Port for water supply
9 Corner decoration cover
10 Drain hose O.D.J32
z When the discharge grill is closed, the
required space is 200mm or more
860890 (Ceiling opening)
Adjustable(0550)
Hanging bolt
1000 mm or
more
Branch duct connection
Required
service space
Prepared hole
1500 mm
or more
Required service space
1500 mm or more
1500 mm or more
1500 mm or more
C view
For fresh air intake kit
connection
(direct installation type)
Branch duct connection
Note 3
300 or less
3TW22874-1
3. In case of using infrared remote controller, this position will be a signal
receiver.
Front grille fixing screws (inside)
4. When it may exceed 30°C and RH 80% in the ceiling or fresh air is
inducted into the ceiling, an additional insulation (Thickness 10mm or
more of glasswool or polyethylene form) is required.
Prepared hole
Branch duct connection
Branch duct connection
Prepared hole
D view
Prepared hole
4-Way Blow Ceiling Mounted Cassette R-22 FH(Y)C35-125B7
13
3
9
Split - Sky Air Indoor Units