Wiring diagrams
3TW22836-1
FHYC35-125B7
33H Float switch
A1P Printed circuit board
C1R Capacitor (M2F)
HAP Light emitting diode (service monitor green)
HBP Light emitting diode (service monitor green)
M1A Motor (swing flap)
M2F Motor (indoor fan)
M3P Motor (drain pump)
Q1F Thermo switch (M2F embedded)
R1T Thermistor (air)
R2T Thermistor (coil)
RyP Magnetic relay (M3P)
SS1 Selector switch (emergency)
T1R Transformer (220-240V/22V)
X1M Terminal strip
X2M Terminal strip
? Signal receiver circuit
. Signal transmission circuit
= Phase control circuit
Wired remote control
SS1 Selector switch (main/sub)
Receiver / display unit (attached to remote control)
A2P,A3P Printed circuit board
BS Push button (on/off)
H1P Light emitting diode (on-red)
H2P Light emitting diode (timer-green)
H3P Light emitting diode (filter sign-red)
H4P Light emitting diode (defrost-orange)
SS1 Selector switch (main/sub)
SS2 Selector switch (wireless address set)
Adapter for wiring
RyC,RyF Magnetic relay
Connector for optional parts
X30A Connector (interface adapter for sky air series)
X33A Connector (adapter for wiring)
X35A Connector (group control adapter)
Norm. emerg.
Wired remote
control
Terminals for operation indicator
Switch box
Adapter for
wiring
Outdoor unit
(Master)
Notes
1. Use copper conductors only.
2. When using the central remote control, see manual for
connection to the unit.
3. X24A is connected when the infrared remote controller kit is
being used.
4. Remote controller model varies according to the
combination system, confirm technical materials and
catalogs, etc. before connecting.
g Field wiring
D Terminal
F : Connector
h : Wire clamp
b : Protective earth (screw)
Colours
BLK: Black / WHT: White / RED: Red / YLW: Yellow
Receiver / display unit
In case of simultaneous
operation system.
Note) 3
(Slave)
Indoor
Outdoor
Remote
control
Fan operation
Compressor operating
3TW22896-1
FHC35-60B7
33H Float switch
A1P Printed circuit board
C1R Capacitor (M2F)
HAP Light emitting diode (service monitor green)
HBP Light emitting diode (service monitor green)
M1A Motor (swing flap)
M2F Motor (indoor fan)
M3P Motor (drain pump)
Q1F Thermo switch (M2F embedded)
R1T Thermistor (air)
R2T Thermistor (coil)
RyP Magnetic relay (M3P)
SS1 Selector switch (emergency)
T1R Transformer (220-240V/22V)
X1M Terminal strip
X2M Terminal strip
? Signal receiver circuit
. Signal transmission circuit
= Phase control circuit
Wired remote control
SS1 Selector switch (main/sub)
Receiver / display unit (attached to remote control)
A2P,A3P Printed circuit board
BS Push button (on/off)
H1P Light emitting diode (on-red)
H2P Light emitting diode (timer-green)
H3P Light emitting diode (filter sign-red)
H4P Light emitting diode (defrost-orange)
SS1 Selector switch (main/sub)
SS2 Selector switch (wireless address set)
Adapter for wiring
RyC,RyF Magnetic relay
Connector for optional parts
X30A Connector (interface adapter for sky air series)
X33A Connector (adapter for wiring)
X35A Connector (group control adapter)
Norm. emerg.
Wired remote
control
Terminals for operation indicator
Switch box
Adapter for
wiring
Notes
1. Use copper conductors only.
2. When using the central remote control, see manual for
connection to the unit.
3. X24A is connected when the infrared remote controller kit is
being used.
4. Remote controller model varies according to the
combination system, confirm technical materials and
catalogs, etc. before connecting.
g Field wiring D Terminal
F : Connector
h : Wire clamp
b : Protective earth (screw)
Colours
BLK: Black / WHT: White / RED: Red / YLW: Yellow
Receiver / display unit
Note) 3
Indoor
Outdoor
Fan operation
Compressor operating
•
4-Way Blow Ceiling Mounted Cassette • R-22 • FH(Y)C35-125B7