NOMINAL CAPACITY and NOMINAL INPUT
For indoor units only:
INDOOR UNITS FHYC71B7V1 FHYC100B7V1 FHYC125B7V1
NOMINAL INPUT Cooling kW 0.161 0.204 0.238
Heating kW 0.161 0.204 0.238
For combination indoor units + outdoor units:
INDOOR UNITS FHYC71B7V1 FHYC100B7V1 FHYC125B7V1
OUTDOOR UNITS RY71B7V1/W1 RY100B7V1/W1 RY125B7W1
NOMINAL CAPACITY (3) Cooling (1) kW 7.30 10.30 12.80
Heating (2) kW 8.70 12.20 15.30
NOMINAL INPUT Cooling kW 3.10/3.00 40/3.80 4.60
Heating kW 3.10/3.00 3.80/3.60 4.70
TECHNICAL SPECIFICATIONS
For indoor units only:
INDOOR UNITS FHYC71B7V1 FHYC100B7V1 FHYC125B7V1
DIMENSIONS Unit H mm 230 288 288
W mm 840 840 840
D mm 840 840 840
Decoration panel H mm 40 40 40
W mm 950 950 950
D mm 950 950 950
WEIGHT Unit kg 23 27 27
Decoration panel kg 5 5 5
MATERIAL Unit Galvanised steel plate
COLOUR Decoration panel White
SOUND LEVEL Sound pressure
(cooling/heating) (4)
high dB(A) 33/33 37/37 40/40
low dB(A) 28/28 32/32 35/35
Sound power (cooling/heating) (5) dB(A) 50/50 53/53 56/56
FAN Air flow rate (cooling/heating) high m
3
/min 18/18 28/28 1/31
low m
3
/min 14/14 21/21 24/24
Speed (cooling/heating) steps 2 steps
Drive Direct drive
Type Turbo fan
Qty x model 1 x QTS46B14M 1 x QTS46A17M 1 x QTS46A17M
Qty x motor output W 1 x 45 1 x 90 1 x 90
HEAT EXCHANGER Type Cross fin coil, J7 Hi-HA tubes
Rows x stages x fin pitch mm 2x8x1.5 2x12x1.5 2x12x1.5
Face area m
2
0.331 0.497 0.497
AIR DIRECTION CONTROL Resin net (with mold resistant)
TEMPERATURE CONTROL Computerised control
PIPING CONNECTIONS liquid mm φ9.5 (flare) φ9.5 (flare) φ9.5 (flare)
gas mm φ15.9 (flare) φ19.1 (flare) φ19.1 (flare)
drain mm VP25 (I.D. φ25)
drain mm VP25 (O.D. φ32)
INSULATION MATERIAL Heat insulation tape Foamed polystyrene
Sound absorbing insulation Foamed polystyrene
For outdoor units
only:
Pair application See chapter R(E)Y
3TW22831-2B
•