VRV IV Technologies
Customize your VRV for best seasonal eciency & comfort with the weather
dependant Variable Refrigerant Temperature function
VRV congurator software
Revolutionary variable refrigerant temperature (VRT) control
automatically adapts your VRV to your individual building and
climate requirements for comfort and eciency, thus drastically
reducing operational running costs.
Optimise the match of building requirements with comfort and eciency
Automatic adjustment of refrigerant temperature guarantees customer satisfaction
Unique VRT automatic mode leads to 28%
increase in seasonal efficiency
In automatic mode the system will go for maximum eciency
throughout most of the year and for quick reaction speed on the
hottest days, ensuring comfort at all times while still resulting in
an increased seasonal eciency up to 28%.
Simplied commissioning
The VRV congurator is an advanced software solution that allows
for easy system conguration and commissioning:
less time is required on the roof conguring the outdoor unit.
multiple systems at dierent sites can be managed in exactly
the same way, thus oering simplied commissioning for key
accounts.
Initial settings on the outdoor unit can be easily retrieved.
Simplied servicing
Outdoor unit display for quick on-site settings and easy read out
of errors together with the indication of service parameters for
checking basic functions.
easy-to-read error report.
indication of basic service parameters to quickly check basic
functions.
clear menu indicating quick and easy on-site settings.
The perfect balance :
Maximum eciency throughout
most of the year. Quick reaction speed
on the hottest days
Top
eciency
Quick reaction
speed
For example, in mid season when there is little cooling
needed and the room temperature is close to the
setpoint, the system will adjust its refrigerant temperature
to a higher temperature so less energy is needed, leading
to major savings in seasonal eciency.
Automatic mode (Default setting on VRV IV)
Load
Refrigerant volume (VRV)
Refrigerant temperature (VRT)
Eciency
Less time needed for commissioning
Manage multiple systems in exactly the same way
Retrieve initial system settings
Simplied
commissioning
Retrieve initial
system settings