13
14
Specifications are subject to change.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 °CDB, 19 °CWB; outdoor temp. 35 °CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 °CDB; outdoor temp. 7 °CDB, 6 °CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a
result of ambient conditions.
Notes: *1. A wiring adaptor (KRP413AA1S) is also required for each indoor unit.
*2. Wiring adaptor supplied by DAIKIN. Time clock and other devices should be obtained locally.
*3. A set of a frameless Titanium Apatite Photocatalytic air-purifying filter and a frameless deodorising filter for the Flash streamer unit. Both filters are standard accessories.
Notes: *1. One set includes 5 pieces for 5 units.
*2. One set includes 10 pieces.
*3. One set includes a 2 m extension hose, 1 joint, and 2 tieraps
Note: * A wiring adaptor (KRP928BA2S) is also required for each indoor unit.
FTXR50EV1B
RXR50EV1B
5.0 (1.55-5.5)
17,100 (5,300-18,800)
6.0 (1.3-6.2)
20,500 (4,400-21,200)
7.2
7.4
1,460 (260-1,800)
1,510 (230-1,770)
3.42
3.97
FTXR50EV1B
13.3 (470)
14.0 (494)
44/29/26
44/31/28
RXR50EV1B
48
50
FTXR28EV1B
RXR28EV1B
2.8 (1.55-3.6)
9,600 (5,300-12,300)
3.6 (1.3-5.0)
12,300 (4,400-16,400)
3.2
3.9
560 (250-800)
700 (220-1,410)
5.00
5.14
FTXR28EV1B
11.1 (392)
12.4 (438)
39/26/23
41/28/25
RXR28EV1B
46
46
FTXR42EV1B
RXR42EV1B
4.2 (1.55-4.6)
14,300 (5,300-15,700)
5.1 (1.3-5.6)
17,400 (4,400-19,100)
5.3
5.9
1,050 (260-1,320)
1,180 (220-1,600)
4.00
4.32
FTXR42EV1B
12.4 (438)
12.9 (456)
42/27/24
42/29/26
RXR42EV1B
48
48
Indoor unit
Outdoor unit
Rated
(Min.-Max.)
Rated
(Min.-Max.)
Rated
Rated
(Min.-Max.)
Rated
kW
Btu/h
kW
Btu/h
A
W
W/W
m
3
/min
(cfm)
dB (A)
mm
kg
W
kg
dB (A)
mm
kg
˚CDB
˚CWB
mm
m
m
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Type
Motor output
Cooling
Heating
Cooling
Heating
Liquid
Gas
Drain
Model name
Capacity
Power supply
Running current (220 V)
Power consumption
COP
Indoor unit
Front panel colour
Airflow rate (H)
Fan speed
Sound levels (H/L/SL)
Dimensions (H x W x D)
Machine weight
Outdoor unit
Casing colour
Compressor
Refrigerant charge (R-410A)
Sound levels (H)
Dimensions (H x W x D)
Machine weight
Operation range
Piping connections
Max. piping length
Max. height difference
Heat pump
1 phase, 220-240 V, 50 Hz
White
5 steps, quiet and automatic
305 x 890 x 209
14
Ivory white
Hermetically sealed swing type
1,100
1.4
693 x 795 x 285
48
-10 to 43
-20 to 24
ø6.4
ø9.5
ø18.0
10
8
FTXR50EV1BFTXR42EV1BFTXR28EV1B
5-room centralised controller*
1
Wiring adaptor for time clock/remote controller*
2
(Normal open pulse contact/normal open contact)
Air purifying filter set*
3
Air supply filter with frame
Remote controller loss prevention chain
ItemNo.
1
2
3
4
5
Indoor units
KRC72A
KRP413AA1S
KAF974B42S
KAF963A43
KKF936A4
RXR50EV1BRXR42EV1BRXR28EV1B
Air direction adjustment grille
Drain plug*
1
Humidity hose extension joint*
2
Humidity hose L cuff*
2
Humidity hose (10 m)
Humidity hose extension set*
3
KPW937AA4
KKP937A4
KPMJ942A4
KPMH950A4L
KPMH942A42
KPMH942A402
ItemNo.
1
2
3
4
5
6
Outdoor units
FTXR50EV1BFTXR42EV1BFTXR28EV1B
DCS302CA51
DCS301BA51
DST301BA51
KRP928BA2S
ItemNo.
1
2
3
4
System configurations
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for D -NET use
Specifications
Options
RXR28/42/50EV1B
5-room centralised
controller
KRC72A
Air purifying filter set
KAF974B42S
Air supply filter with frame
KAF963A43
Drain plug
KKP937A4
Humidity hose L cuff
KPMH950A4L
Central remote controller
DCS302CA51
Unified on/off controller
DCS301BA51
Schedule timer
DST301BA51
GOOD
DESIGN
AWARD
IN JAPAN
Humidity hose extension set
Komentarze do niniejszej Instrukcji