3
4
Humidifier unit
Extracts moisture
from outdoor air.
Humidifies the indoor air.
Outdoor unit
Tendency to
humidify unevenly
Even humidification
Humidified heating
Feels chilly
Feels pleasantly warm
Humidified heating
*1. Household air conditioners using a humidification system not requiring a separate water supply (current as of April, 2006).
*2. Humidification capacity measurement conditions: Outdoor temperature 7°CDB, 6°C WB (heating capacity measurement conditions). Humidification capacity drops when outdoor
temperature and humidity are low. Actual humidity may not reach the exact level if the ventilation air volume is high or the temperature setting is high. Maximum power consumption of humidifier
heater is approximately 560 W. Level is controlled between 0 W and maximum power consumption. Operation pattern during humidifying operation may differ due to factors such as customer
settings, room size, ventilation frequency, and temperature and humidity conditions.
*3. Ururu Sarara is not intended for use as a medical device.
30.0 35.0
˚C
Studies by Daikin show that at 30% relative
humidity, perceived warmth c hanges by
approximately 1°C .
Room temperature: 28°C
Relative humidity: 20%
If the air is dry, you don’t feel warm even
if the temperature is raised.
If the air is moist, you feel warm even
at a lower temperature.
The humidity may not reach the exact level due to the effects of indoor or outdoor conditions.
Dry air is ideal for the spread of viruses.
Ururu humidifying operation
lets you keep the air optimally moist.*
3
It is understood that the mortality rate of viruses rises when the relative
humidity is 40% or higher. Ururu humidifying operation maintains the
moisture in the air so that viruses have difficulty propagating.*
2
Using a humidifier unit in the outdoor unit, the Ururu humidifying operation function extracts
moisture from outdoor air and uses it to raise the moisture level of the indoor air throughout the
room. The system is very hygienic because there is no water tank requiring periodic refilling.
Daikin s exclusive system requires no separate water supply,*
1
so there is no need to add water and no worries about mould.
Ururu humidifying operation is the ideal form
of winter heating because it combines the
functions of an air conditioner (heater) and a
humidifier in a single system. The powerful
humidifying function spreads warm,
moisturised air evenly to every corner of the
room. Humidity is maintained at the ideal
level for skin that is sensitive to dryness.
Moisture is added to the warm air flowing into the room, so even a large living room is humidified evenly.
The dryer the air, the less our bodies
perceive the warmth around us. Ururu
humidifying operation humidifies the indoor
air just the right amount so that you feel
comfortably warm even at a relatively low
temperature setting.
Perceived warmth is heightened, helping to avoid excess heating. Humidified heating is gentle to the human body.
Humidification volume
(volume of moisture added to air per hour*
2
)
FTXR28E
400 ML/ h
FTXR42E
425 ML/ h
FTXR50E
450 ML/ h
Above figures are for c ontinuous humidification
operation.
B ec ause the Ururu Sarara us es a different
humidific ation method from conventional humidifiers, the
ac tual humidification volume varies depending on
outdoor conditions and ins tallation details.
Humidification volume is reduced by approximately 15% when
the outdoor temperature drops by 5°C .
Humidification volume is reduced by approximately 20% when
the outdoor relative humidity drops by 20%.
A humidifier hose length (piping length) of 7.5 metres is used
as the standard. Extending the hose length by 2 metres will
(Results of Daikin experiment)
Ururu
humidifying
opera
tion
Humidifies the
indoor air.
No need to replenish
water supply.
Adds moisture to the air to maintain
a comfortable humidity level even during dry
weather.
The thermograph shows the temperature
distribution on the skin surface 30 minutes after
entering the room.
Room temperature: 22°C
Relative humidity: 50%
Extracts moisture
from outdoor air.
Humidifier only
Humidified heating
Humidified air tends
to collect near the ceiling.
Humidified air spreads
evenly throughout the room.