19 English
9-5 CONTROL BY 2 REMOTE CONTROLLERS
(
Controlling 1 indoor unit by 2 remote controllers
)
When using 2 remote controllers, one must be set to MAIN and the other to SUB.
MAIN/SUB CHANGEOVER
1. Insert a wedge-head screwdriver into the recess between the upper and lower parts of remote con-
troller and, working from the 2 positions, remove carefully the upper part. (Refer to Fig. 22)
(The remote controller PC board is attached to the upper part of the remote controller.)
2. Turn the MAIN/SUB changeover switch on one of the two remote controller PC board to S.
(Leave the switch of the other remote controller set to M.) (Refer to Fig. 23)
9-6 COMPUTERISED CONTROL (FORCED OFF AND ON/OFF OPERATION) FOR FAQ MODEL
(1) Wire specifications and how to perform wiring
Connect input from outside to terminals T1 and T2 of the terminal block for remote controller.
(2) Actuation
The following table explains FORCED OFF and ON/OFF OPERATIONS in response to Input A.
(3) How to select FORCED OFF and ON/OFF OPERATION
Turn the power on and then use the remote controller to select operation.
Wire specification Sheathed vinyl cord or cable (2 wire)
Gauge
0.75 - 1.25 mm
2
Length Max. 100 m
External terminal Contact that can ensure the minimum applicable load of 15 V DC, 10 mA.
FORCED OFF ON/OFF OPERATION
Input ON stops operation (impossible by remote controllers.) Input OFF ON turns ON unit.
Input OFF enables control by remote controller. Input ON OFF turns OFF unit.
Lower part of
remote controller
Upper part of
remote controller
Fig. 22
Insert the screwdriver here and gently
work off the upper part of remote controller.
S
M
S
S
M
Factory setting
Only one remote controller
needs to be changed
if factory settings have
remained untouched.
Remote
controller
PC board
Fig 23
F2 T1 T2
FORCED
OFF
Input A