Indoor Unit Si04-402
128 Removal Procedure
1.8 Removal of Vertical Blades and Swing Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
Remove the assembly of
the outlet grille.
1. Remove the vertical
blades.
1
Release the 4 hooks
and remove the thermal
insulation.
2
Release the 4 hooks
and remove the thermal
insulation.