Daikin FTXG35CVMBS Dokumentacja Strona 176

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 175
Si04-402 Outdoor Unit
Removal Procedure 167
2.7 Removal of PCB
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the PCB.
You can remove the PCB
when you disconnect the
read wires on the terminal
board without removing the
electrical box.
PbF (Pb free brazing) is
adopted.
1
Feature of the PCB
2
Loosen the screw on
the terminal board.
3
Release the earth
terminal.