Si04-402 Indoor Unit
Removal Procedure 147
1.12 Removal of Fan Rotor and Fan Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the right side
plate.
1
Loosen the 2 screws.
2
Remove the right side
plate.
2. Remove the motor cover.
1
Loosen the 2 screws
and remove the motor
cover.